Search results for "PV"

Results 1 - 10 of 11 Page 1 of 2
Sorted by: Relevance | Sort by: Date Results per-page: 10 | All

Albania

[…]ne ju ofrojme te gjithe komponentet e sistemit per drejtimin e nivelit te ujit: membrane EVA-PVC , profilet e aluminit, elementet drenazhues, ajruesit e tarracave termike, sistemet e ndricimit natyral dhe shume elemente te tjere. Nepermjet produkteve inovative, dekada vite experienc dhe keshillimit individual realizojme zgjidhjen e cdo problemi ne tarraca. Partneret tane profesional mund tiu ndihmojne ju me […]

Weser Stadium

[…]Ingenieurges. für wirtschaftl. Bauen mbH, Installers: Arbeitsgemeinschaft PV-Dach Weser-Stadion: W & M Flachdachbau Bremen Schneider Dach & Fassade GmbH. Papenburg Schneider Dach Fassade GmbH. Westerstede Material / thickness in mm: EVALON® V SOLAR Type of work: refurbishment Date of construction: 2008 – 2010 Roof area m²: ca. 18.000 Solar area […]

Convincing reliability

[…]With its high polymer alloy of ethylene vinyl acetate terpolymer (EVA) and polyvinyl chloride (PVC) it is installed as a single-ply waterproofing in all climatic zones of the world. The high percentage of high polymeric solids ensures consistent properties and an extremely long service life of the 150 million square metres of membranes installed by now. At the same time, the bright and smooth surface is dirt-repellent and reflects heat radiation. EVALON® is resistant to root and rhizome penetration according to current FLL testing and suitable for direct application on green roofs without any additional root protection layer. Depending on […]

4 Waterproofing concept for the roof area

[…]g. EVALASTIC® V with polyester fleece backing Marking according to DIN 18195-2 BA EVA-BV-K-PV-1.5 BA= waterproofing for foundations EPDM= description of synthetic material BV= bitumen-compatible K= backing PV= polyester fleece 1.5= membrane thickness in mm without backing » Seam overlap EVALASTIC® waterproofing membranes are marked with several dashed lines along one longitudinal edge. These markings can be used as guiding lines for the corresponding lap width and are approx. 5 cm for bonding and loose laying under ballast (min. overlap 4 cm) approx. 11 cm for load distribution plates 40 x 82 mm approx. 12 cm for load distribution plates Ø 50 mm […]

alwitra water spouts

alwitra water spouts are made of rigid PVC and, depending on the version, are equipped either with a welding flange for EVALON® waterproofing membranes or with a factory-fitted flashing collar made of EVALON®. Along with the alwitra water spouts for pipes with various diameters, rectangular versions are also available. These rectangular water spouts feature particularly high discharge rates at low ponding […]

4 Waterproofing concept for the roof area

[…]layer) e. g. EVALON® V with polyester fleece backing Marking according to DIN 18195-2 BA EVA-BV-K-PV-1.5 BA= waterproofing for foundations EVA= description of synthetic material BV= bitumen-compatible K= backing PV= polyester fleece 1.5= membrane thickness in mm without backing » Seam overlap EVALON® waterproofing membranes are marked with several dashed lines along one longitudinal edge. These markings can be used as guiding lines for the corresponding lap width and are • approx. 5 cm for bonding and loose laying under ballast (min. overlap 4 cm) • approx. 11 cm for load distribution plates 40 x 82 mm (mechanical fastening) • approx. […]

13 Flashing of edge trim profiles and integrated details

[…]not to damage the kerb. » Flashing of other rooflights and smoke and heat vents (not made of PVC) Other kerbs, if not made of PVC, must be coated up to the dome around the circumference with self-adhesive EVALON® VSKA tapes (bonded), fixed on the top edge against sliding away and covered to make them rainproof.    13.6 Flashing of arcade rooflights to the roof waterproofing Flashings of arcade rooflights are either carried out like wall flashings (see chapter 11), or unbacked EVALON® tapes or self-adhesive EVALON® VSKA tapes are integrated into the arcade rooflights structure42. 42 To be confirmed with the manufacturer of […]
Read more » 13 Flashing of edge trim profiles and integrated details

Upstands

[…]corner: U-value: 1.0 W/m²K according to EN 12567-2 white inner side, smooth or lightly textured PVC CE marking in connection with alwitra rooflights according to DIN EN 1873 EVALON® and EVALASTIC® collars for perfect and fast waterproofing alwitra upstands are optionally available with factory-fitted EVALON® or EVALASTIC® collars. With this collar a tight and homogeneous flashing against the roofing membrane can be achieved far quicker than with manual flashing: completely pre-assembled at the factory full-size adhesive bond of the flashing collar on the upstand material thickness of the sealing layer: 1.5 mm available in any roofing membrane colour professional top […]

EVALASTIC® – the best waterproofing combination of ecology and economy

[…]Visitor Centre high-quality EPDM membrane absolutely free from bitumen, plasticizers, PVC, chlorine or the like bitumen-compatible compatible with all kinds of insulation materials homogeneous on-site seam welding by simple and environmentally friendly hot air jointing outstanding resistance to chemicals and weathering extremely high resistance to low temperatures universally applicable in all climate zones exemplary life cycle assessment results: long service life with carefully selected resources can be recycled Please find our Safety Data Sheets here. Variants and accessories EVALASTIC® V EVALASTIC® VGSK EVALASTIC® VSKA standing seam profile maintenance walkway tile Polyester fleece backing as a compensation layer - perfectly suited […]
Read more » EVALASTIC® – the best waterproofing combination of ecology and economy